7
INSTRUCTIONS
SPECIFICATIONS
Typical test conditions, unless otherwise specified: Ambient Temp=23+/-3°C, RH=50%-70%,
Altitude=0 meters
MEASUREMENT SPECIFICATION
Operating Temperature 32°F to 122°F (0°C to 50°C)
Storage Temperature -4°F to 140°F (-20°C to 60°C)
Operating & Storage RH 0-95%, non-condensing
CO
2
MEASUREMENT
Accuracy at 0-3000 ppm ±50 ppm or ±5% of reading, whichever is greater
Accuracy over 3000 ppm ±7%
Repeatability 20 ppm at 400 ppm (standard dev. of 10 readings in 1 minute)
Measurement Range 0-5000 ppm
Display Resolution 1 ppm (0-1000); 5 ppm (1000-2000); 10 ppm (>2000)
Temp Dependence
±0.1% of reading per °C or ±2 ppm per °C, whichever is greater,
referenced to 25°C
Pressure Dependence 0.13% of reading per mm Hg (corrected by user’s altitude input)
Response Time <2 min for 63% of step change or <4.6 min for 90% step change
Warm-up Time <30 sec
TEMP MEASUREMENT
Operating Temperature 32°F to 122°F (0°C -50°C)
Display Resolution 0.1°F (0.1°C)
Accuracy ±1°F (±0.5°C)
Response Time <20 min (63%)
RH MEASUREMENT
Range 10-90%
Accuracy ±5%
Resolution 1% on Main Reading, 0.1% on Max Min Reading
Power Requirements 160 mA Peak, 15 mA average at 5.0V
Optional Battery
Battery Pack is not included. Theoretical calculation (for
reference only, not a guarantee): For a 5000 mAh battery, 200
hrs/8.3 days
Dimension 120 x 91.2 x 27 mm (4.7 x 3.6 x 1.1 inch)
Weight 148 g (5.22 oz)
Device onlyAC adapter not included in this weight
DISCLAIMERS:
USB connection is for power supply only; it cannot communicate with a PC. Unplugging the
device may result in loss of most recent logged data on the chart.
This device is not intended for workplace hazard CO
2
monitoring, nor intended as a definitive
monitor for human or animal health institutions, life sustenance, or any medical-related situation.
Hydrofarm assumes no responsibility for any damage or loss suffered by the user or any third
party arising through the use of this product or its malfunction.
Hydrofarm reserves the right to change the spec without notice.
Note: This device can be powered by an external baery pack (not included). Baery capacity:
larger or equal to 4000 mAh (3000 mAh sll works, with reduced baery life). Recommended bat
-
tery size: smaller than 101 x 60 x 22 mm/4.0" x 2.4" x 0.87" (a slightly larger baery works, but is
not easy to t in the aached velcro strap).

Other manuals for Hydrofarm Autopilot APCEM2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hydrofarm Autopilot APCEM2 and is the answer not in the manual?

Hydrofarm Autopilot APCEM2 Specifications

General IconGeneral
BrandHydrofarm
ModelAutopilot APCEM2
CategoryMonitor
LanguageEnglish

Related product manuals