Troubleshooting 2000 SRM 1025
PROBLEM POSSIBLE CAUSE PROCEDURE OR ACTION
Lift pump and mo
tor oper-
ates but the mas
t will not
raise. The butt
on is in the
raise positio
n.
Oil in the hydra
ulic reservoir is low.
Fill reservoir
to correct level. Check
for leaks.
Lift/lower co
il is defective.
Measure the re
sistance on the coil
and replace if
not correct.
EV1 - 17.7
EV2 - 22.5
Lift/lower ca
rtridge is defective.
Check for 0.5 t
o 0.8 amps of current
at the coil of
the cartridge. Check
wiring for lo
ose or bad connections.
Check the val
ve cartridge for contam-
ination and d
amage. Replace car-
tridge.
24