EasyManuals Logo

IBC EX 850 Quick Start Guide

IBC EX 850
8 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
120-334E-R1
| 1
Note
Ifconvertingtopropane,orderthePropaneConversionPartskit(IBCPart#P-1201)fromyourauthorizedIBC
distributor.
UsetheNaturalGasConversionkitifthefuelsourceatthesiteusesnaturalgasandthemodulatingboilerhasbeenset
up(factoryfire-tested)tooperatewithpropane.Checktheratingplateontheboilertoseewhichfuelsourcetheparticular
boilerhasbeensetupwith.
Usingthisconversionkit,aqualifiedtechnicianwillneedto:
1. Performafuelconversion.
2. Performacombustiontest.
3. Fillintheinformationrequiredonthefuelconversionlabels,andaffixthemtotheboileraftertheconversionis
completed.
Warning
Thisconversionkitshallbeinstalledbyaqualifiedserviceagencyinaccordance
withthemanufacturersinstructionsandallapplicablecodesandrequirementsof
theauthorityhavingjurisdiction.Iftheinformationintheseinstructionsisnot
followedexactly,afire,anexplosionorproductionofcarbonmonoxidemayresult
causingpropertydamage,personalinjuryorlossoflife.
Thequalifiedserviceagencyisresponsiblefortheproperinstallationofthiskit.The
installationisnotproperandcompleteuntiltheoperationoftheconvertedappliance
ischeckedasspecifiedinthemanufacturersinstructionssuppliedwiththekit.
Theboilerwillautomaticallyde-ratethemaximuminputatarateofapproximately2%per1,000'above4,500'.Thegas
valveszerogovernorwillensurethatthegas-airmixtureisnotaffectedataltitude.
Includedwiththeconversionkit:
1xNGMixerAssembly-IBCPart#180-254 4xHexboltM6x14SS-IBCPart#150-373
1xO-ringgasvalvecoupler-IBCPart#150-001 1xRatingPlateFuelOverlay-IBCPart#080-285A
4xHexboltM5x25IBCPart#150-354 1xGasValveConversionLabel-IBCPart#080-107B
4xFlatWasher,0.562ID-IBCPart#150-025 1xInstallerIdentifierLabel-IBCPart#080-283A
4xM6FlatWasherIBCPart#150-159 6xHexboltM8x14-IBCPart#150-329
6xM8Flatwasher-IBCPart#150-339 1xO-ringEBMblower-IBCPart#150-376
Thisconversioninvolveschangingthemixingassembly.
EX 700 - Fuel Conversion to Natural Gas
(LP to NG) P-Kit 1200

Other manuals for IBC EX 850

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBC EX 850 and is the answer not in the manual?

IBC EX 850 Specifications

General IconGeneral
CategoryBoiler
BrandIBC
ModelEX 850
Fuel TypeNatural Gas or Propane
EfficiencyUp to 95% AFUE

Related product manuals