Qscan User’s Guide Version 1.4
Page 39
Proximity and iClass Input, Format # 2, Part 2*
X051 iss il b sc ic uc
iss issue code start bit max=250
il # bits for issue code 000=no issue
b issue code is lsb 0=off 1=issue is lsb
sc site characters 00=none max=20
ic id characters 00=none max=20
uc issue characters 00=none max=20
This command is the second part of a 2 part command, for setting up an
input proximity or iClass format.
* added to rmware 5/22/13
PROGRAMMING
PROX ICLASS
Proximity and iClass Input, Format # 3, Part 1*
X052 bbb sss sl b bss bl x
bbb # card bits max=250
sss site start bit 000=no site
sl # bits for site code 00=none
b site is lsb 0=off 1=site is lsb
bss id start bit 000=no id
bl # bits for id 00=none
x id is lsb 0=off 1=id is lsb
This command is the rst part of a 2 part command, for setting up an
input proximity or iClass format.