IBERITAL DE RECAMBIOS, S.A.
Page 15 of 22 manual electr.ce ingles 22-11-2004.doc
When the programing has finished turn the On-Off switch to the Off (position 0) and get out
the link
IX. PROGRAM OF THE CONTINUOUS BUTTON AS HOT WATER
OR CONTINUOUS. (FOR IBERITAL MODELS 2 gr and 3 gr only)
Programming the continuous button (
*
) as Hot Water button
1) Turn Off (position 0) the On-Off switch.
2) Press the 2 short coffees button, the hot water button and turn On (position 2) the On-
Off switch at the same time.
3) The Leds of the 2 short coffees and 2 long coffees will light.
4) Stop pressing the buttons and turn Off (position 0) the On-Off switch
5) Turn On (position 2) the On-Off switch
Programming the 5
th
button (
*
) as Continuous
The 5th button function (*) will be continuous erogation and the external hot water button, as
hot water button.
1) Turn Off (position 0) the On-Off switch.
2) Press the 2 long coffees button, the hot water button and turn On (position 2) the On-
Off switch at the same time
3) The Leds of the 2 long coffees and the continuous will light.