SurePOS 500-XX3 relies on convection cooling so placement requires the ambient air adjacent to the unit
does not exceed supported maximums. The vents cannot be blocked to prevent access to ambient air.
Spill/Chemical Resistance
The system unit will be designed to meet the following standards for liquid spill resistance when mounted in
normal configurations. The spill specification does not apply to the cable attached I/O devices such as the
distributed customer display or scanners:
IBM RSS Chemical Resistance Test
NEMA Type 5 rating per NEMA Standards Publication/No. 250-1997 Enclosures for Electrical
Equipment (National Electrical Manufacturers Association)
IP 52 rating per IEC 529 (Degrees of Protection by enclosures (IP Code)
Internally tested to IP 52 but not declared in safety report.