TAPE READ
MAP
PAGE
36
OF
45
394
~Calibrate
the
CE
meter (refer
to
270).
~Measure
greater than 1 vdc between tape
control card pin
010
(+
BOTPTX
collector) and
tape control card pin
uoa
(gnd) (refer
to
227),
Is
the
voltage
greater
than
1 vdc7
Y N
395
Defective tape control card (refer
to
202).
Defective tape LED-PTX assembly (refer
to
~02).
Check/replace the tape internal cable (refer
to
202).
396
-If
there is a cartridge
in
the tape drive, remove it.
-Remove tape control card (refer
to
20Z).
-Probe F2-UlO (-beginning
C)f
tape).
-Leave the probe on the pin.
Is
the
DOWN
light
on
7
Y N
397
Is
the
UP
light
on7
Y N
398
Defective
F2
(base
I/O)
card,
399
Defective tape control card (refer
to
202).
400
-Disconnect the tape qrive cable from the board
(refer
to
228).
Is
the
DOWN
light
on?
Y N
3 3
6 6
F F
B C
A F F
~ ~
~
6 6
MAP 0300-36
401
Check/
replace
the
tape driv\'l cable (refer
to
202).
402
Defective
F2
(base
I/O)
card.
403
ERROR
918--STATUS ERROR.
Status indicates the the
LED
used
for
detecting
BOT-EDT is
not
on (status bit 5 was
0,
should
have been
1).
NOTE: ALL
PROBES
OR
METI:R TESTS
FOR
THIS
ERROR
REQUIRE THAT THE GROUND
WIRE
OF
THE
PROBE
OR
METER
BE
ATTACHED TO N2-p08 (GND).
(refer
to
the appendix, the general logic probe),
-Probe F2-J13 (-
LED
and
eraSe
ok).
Is
the
UP
light
on7
Y N
404
Defective
F2
(base
I/O)
card,
405
-Probe tape control card pin 507 (- LI:O and
erase ok) (refer
to
227).
Is
the
UP
light
on7
Y N
3
7
F
D
406
Check/replace the tape drive cable (refer
to
202).
~8SEP76
PN
1(i08386
EC8Z9670
PEC
828851
MAP 0300-36