F
o
3
6
TAPE READ
MAP
PAGE 37
OF
45
407
-Calibrate the
CE
meter (refer to 270).
-Measure greater than
+8
vdc between tape
control card pin
B11
(+
LED
conducting) and
N2-POB
(gnd).
Is
the
voltage
greater
than
+8
vdc
7
Y N
408
-Measure +12 vdc between tape control card
pin
D11
(+12
vdc) and
N2-POB
(gnd).
Is
the
voltage
in
tolerance
(+11.0
vdc
to
+13.2 vdc)7
Y N
409
(Entry
Point
C)
-Measure +12 vdc between
tape
control
card pin 511
(+12
vdc) and
N2-POB
(gnd).
Is
the
voltage
in
tolerance
(+11.0
vdc
to
+13.2 vdc)?
Y N
410
'-If
there is a cartridge in the tape drive.
remove it.
-Remove tape control card (refer
to
202).
-Measure + 12 vdc between tape cOntrol
card pin 511 (+12 vdc) and N2-P08
(gnd).
Is
the
voltage
in
tolerance
(+11.0
vdc
to
+13.2 vdc)?
Y N
3 3
333
8 7 7 7
7,
F F F F F
E F G H
J
F F F F
F G H
J
3 3 3 3
7 7 7 7
MAP
0300-37
411
-Install the tape control card (refer
to
202).
-Measure
+12
vdc between F6-D02
(+
12
vdc) and
N2-POB
(gnd).
Is
the
voltage
in
tolerance
(+11.0
vdc
to
+13.2 vdc17
Y N
412
-Measure +12 vdc between C1-D13
(+
12 vdc) and N2-POB (gnd).
Is
the
voltage
in
tolerance
(+11.0
vdc
to
+13.2 vdc)7
Y N
413
+ 12 vdc is
not
in
tolerance.
Go
to
MAP
0700,
Entry
Point
A.
414
Repair the open connection between
C1-D13 and F6-D02 .
415
Check/replace the tape drive cable
(refer
to
202).
416
Defective tape control card (refer
to
202).
417
Defective tape control card (refer
to
202).
418
Defective tape LED-PTX assembly (refer to 202).
Check/replace the tape internal cable (refer
to
202).
28SEP76
PN
160B386
EC
829670
PEC
828851
MAP
0300-37