Note: The rails are not designed to hold an enclosure that is partially inserted. Always
fully insert the enclosure in the rack.
4. Secure the enclosure with a screw in each of the rack mounting screw holes.
5. Reinstall the left and right end caps.
a. Ensure that the serial number of the end cap matches the serial number on the rear of the
enclosure.
b. Fit the slot on the top of the end cap over the tab on the chassis flange.
c. Rotate the end cap down until it snaps into place.
d. Ensure that the inside surface of the end cap is flush with the chassis.
Note: Indicator windows on the left end cap align with the status LEDs (light-emitting
diodes) on the edge of the enclosure.
Connecting SAS cables
This task applies if you are installing one or more SAS-attached 2U expansion enclosures to your system.
About this task
For information about 5U expansion enclosures, see IBM Documentation (https://ibm.biz/BdqxdY) for your product. The following table
summarizes the supported SAS chains and enclosures for each system. Follow the guidelines to ensure that your conguration is valid.
System
Onboard SAS Ports SAS Chains Expansion Enclosures per Chain I/O Groups Maximum Enclosures
FlashSystem 5015 Port 1 only 1
2U enclosure (10)
5U enclosure (4)
1
2U enclosure (10)
5U enclosure (4)
the FlashSystem 5035 Port 1 and Port 2 2
2U enclosure (10)
5U enclosure (4)
2
2U enclosure (40)
5U enclosure (16)
Procedure
1. Using the supplied SAS cables, complete the following steps to connect the control enclosure to the expansion enclosure.
a) Connect SAS port 1 of the left node canister in the control enclosure to SAS port 1 of the left expansion canister in the rst expansion
enclosure.
b) Connect SAS port 1 of the right node canister in the control enclosure to SAS port 1 of the right expansion canister in the rst
expansion enclosure.
2. On the FlashSystem 5035 systems, complete the following steps to add a second expansion chain.
a) Connect SAS port 2 of the left node canister in the control enclosure to SAS port 1 of the left expansion canister in the second
expansion enclosure.
b) Connect SAS port 2 of the right node canister in the control enclosure to SAS port 1 of the right expansion canister in the second
expansion enclosure.
3. If more expansion enclosures are installed, connect each one to the previous expansion enclosure in a chain.
Results
The following gures show SAS connections between 2U expansion enclosures and each system. SAS chain one (1) is below the control
enclosure. If the system supports a second SAS chain, SAS chain two (2) is above the controle enclosure.
6
Question and Answer IconNeed help?

Do you have a question about the IBM FlashSystem 5000 and is the answer not in the manual?

IBM FlashSystem 5000 Specifications

General IconGeneral
Form Factor2U
EncryptionYes
Operating SystemIBM Spectrum Virtualize
ProcessorIntel Xeon
Host Interface16Gb FC, 10Gb iSCSI, 12Gb SAS
Drive TypesSSD
RAID Levels0, 1, 5, 6, 10
Controller TypeDual Active-Active

Summary

Sign up

About this task

Information about signing up for an IBM Spectrum Virtualize product.

Procedure

Steps required to sign up, including IBM ID creation and hardware registration.

Overview

Important Notes

Key safety and documentation references before using the system.

Planning Worksheets

Information on using worksheets for system planning and installation.

Network Cable Connection Worksheet

Ethernet Connections

Details on Ethernet ports per node canister and their connections.

Ethernet Cable Standards

Specifications for Ethernet cables, including port types, standards, and connectors.

Ethernet Port Connections

Tables for planning Ethernet connections to onboard and optional adapter ports.

Fibre Channel Connections

Instructions for recording Fibre Channel port connections for optional adapters.

SAS Connections

SAS Connections

Table to record SAS port connections for optional SAS adapters.

Management and Service Address Worksheet

Management and Service Address Worksheet

Worksheet to record management and service addresses for control enclosures.

Unpacking and Verifying Contents

Unpacking and Verifying Contents

List of items to check before starting the installation process.

Installing Support Rails

Procedure

Step-by-step guide for installing support rails in a rack cabinet.

Installing Enclosures

Before You Begin

Important cautions and requirements before installing the enclosure.

Procedure

Steps for physically installing the control enclosure into the rack.

Connecting SAS Cables

About This Task

Information on supported SAS chains and enclosures for expansion.

Procedure

Steps to connect control enclosure to expansion enclosures using SAS cables.

Connect Networking Cables

FlashSystem 5015 Onboard Ports

Location and purpose of onboard ports on the FlashSystem 5015.

FlashSystem 5035 Onboard Ports

Location and purpose of onboard ports on the FlashSystem 5035.

Connecting Ethernet Cables

Connecting Ethernet Cables

Instructions for connecting Ethernet port 1 and optionally port 2.

Connecting Other Networking Cables

Connecting Other Networking Cables

Details on optional networking adapters and cable connections.

Powering On the System

Attention: Powering On

Cautionary note about powering on the system with open bays.

Procedure

Steps for powering on the control enclosure and checking status LEDs.

Initializing the System

Before You Begin

Prerequisites and considerations before starting system initialization.

Procedure

Steps to configure an Ethernet port for system initialization via DHCP or manual settings.

Alternative Initialization Method

Alternative Initialization Method

Steps to initialize the system using the service assistant tool or CLI.

Browser Considerations

Browser Considerations

Supported browsers and required features for the management GUI.

Safety and Environmental Notices

Safety and Environmental Notices

Guidance on reviewing safety, environmental, and emission notices.

Compliance Standards

Compliance Standards

Information on product design, testing, and certification standards.

Notices

Notices

Information regarding product availability, patents, and IBM's warranty.

Trademarks

Trademarks

List of IBM and other company trademarks.

Homologation Statement

Homologation Statement

Statement on product certification for public telecommunications networks.

Electromagnetic Compatibility Class A Notices

Canada Notice (Class A)

Canadian notice for Class A digital devices regarding radio and TV interference.

European Community and Morocco Notice (Class A)

EU conformity notice for Class A electromagnetic compatibility requirements.

Germany Notice (Class A)

Germany Notice (Class A)

German EU directive compliance for Class A devices and EMVG law.

Japan Voluntary Control Council for Interference (VCCI) Notice

Japan VCCI Notice (Class A)

VCCI notice for Class A devices, advising on potential residential interference.

Korea Notice

Korea Notice

Notice for Korean users regarding suitability for business environments.

People's Republic of China Notice

China Notice

China notice for residential use, cautioning about radio interference.

Russia Notice

Russia Notice

Russian notice for Class A products in residential areas causing radio interference.

Taiwan Notice

Taiwan Notice

Taiwan notice for Class A IT equipment regarding residential use.

United Kingdom Notice

United Kingdom Notice

UK notice regarding residential use and electromagnetic emissions.

United States Federal Communications Commission (FCC) Notice

United States FCC Notice (Class B)

FCC notice for Class B digital devices, compliance, and interference.

Electromagnetic Compatibility Class B Notices

Canada Notice (Class B)

Canadian notice for Class B digital devices regarding radio and TV interference.

European Community and Morocco Notice (Class B)

EU conformity notice for Class B electromagnetic compatibility requirements.

Germany Notice (Class B)

Germany Notice (Class B)

German EU directive compliance for Class B devices and EMVG law.

Japan Voluntary Control Council for Interference (VCCI) Notice

Japan VCCI Notice (Class B)

VCCI notice for Class B devices, advising on potential residential interference.

Taiwan Notice

Taiwan Notice

IBM Taiwan contact information for product services.

United States Federal Communications Commission (FCC) Notice

United States FCC Notice (Class B)

FCC notice for Class B digital devices, compliance, and interference.

For Your Reference

For Your Reference

Links to IBM documentation, support, and fix central resources.

Related product manuals