v No: Continue with the next step.
v Yes: Go to step 12 (See page 107).
9. Does either the Disk Configuration Error Report, the Disk Configuration Attention Report, or the Disk
Configuration Warning Report display appear with one of the following listed?
v Missing disk units in the configuration
v Missing mirror protection disk units in the configuration
v Device parity protected units in exposed mode
– Yes: Continue with the next step.
– No: Go to step 11 (See page 107).
10.
Select option 5, press F11, and then press Enter to display details.
Does an SRC appear in the Reference Code column?
v No: Continue with the next step.
v Yes: Go to step 12 (See page 107).
11. Look at all the Product activity logs by selecting Product activity log under DST.
Is an SRC logged as a result of this IPL?
v Yes: Continue with the next step.
v No: The last device you disconnected is the failing item. Exchange the failing device and reconnect
the devices that were disconnected previously.
Note: Before exchanging a disk drive, you should attempt to save customer data (see the
Recovery procedures).
This ends the procedure.
12.
Record the SRC on the Problem summary form (see Problem summary form).
Is the SRC the same one that sent you to this procedure?
v No: Continue with the next step.
v Yes: The last device you disconnected is not the failing item.
a. Leave the device disconnected and go to step 7 (See page 106) to continue isolation.
b. If you have disconnected all devices that are identified by FI code FI01106 except the
load-source disk unit, reconnect all devices. Then, go to step 15 (See page 107).
13.
Does either the Disk Configuration Error Report, the Disk Configuration Attention Report, or the Disk
Configuration Warning Report display appear with one of the following listed?
v Missing disk units in the configuration
v Missing mirror protection disk units in the configuration
v Device parity protected units in exposed mode
– Yes: Continue with the next step.
– No: Use the reference code to correct the problem.
This
ends the procedure.
14.
Select option 5, press F11, and then press Enter to display details.
Are all the reference codes 0000?
v No: Use the reference code to correct the problem.
This ends the procedure.
v Yes: The last device you disconnected is the failing item.
a. Reconnect all devices except the failing item.
b. Before exchanging a disk unit, go to the disk unit Remove and replace procedure for the model
you are working on.
This
ends the procedure.
15.
Was disk unit 1 (the load-source disk unit) a failing item that FI code FI01106 identified?
Analyze hardware problems 107

Table of Contents

Other manuals for IBM iSeries 270

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM iSeries 270 and is the answer not in the manual?

IBM iSeries 270 Specifications

General IconGeneral
BrandIBM
ModeliSeries 270
CategoryServer
LanguageEnglish

Related product manuals