Failing item code Description/Action
FI01040 FI01040 indicates that you have an OptiConnect system, and the error is on an iSeries
(TM)
server that is connected to it.
FI01101 FI01101 indicates that the addressed IOA card on the I/O processor is the failing item.
Perform the following:
1. Determine the address of the IOA card (see SRC address formats).
2. Determine the location of the IOA card (see Locations and addresses).
3. Exchange the failing device. Use the device type to determine the part.
FI01103 FI01103 and FI01104 indicate that an attached IOA card is the failing item.
Perform Bus-PIP5 to isolate the failing IOA.
FI01104 See FI01103 (See page 265).
FI01105 FI01105 indicates that the addressed storage device is the failing item.
Perform the following:
1. Is the device location information available in the Service Action Log?
v No: Continue with the next step.
v Yes: Exchange the failing item. See Recovery procedures.
Note: If the failing item is in a migration tower, go to the recovery procedures in the
Migrated Expansion Tower Problem Analysis, Repair and Parts manual on the V5R1
Supplemental Manuals web site
.
This
ends the procedure.
2.
Find the IOP address and the device address (see SRC address formats).
3. To determine the location of the I/O processor card, see Locations and addresses and
find the diagram of the system unit or the expansion unit. Then, find:
v The IOP card location identified by the direct select address.
v The addressed storage device location identified by the device address.
4.
Exchange the failing device. Use the device type to determine the part.
FI01106 FI01106 indicates that a storage device other than the addressed storage device is the
failing item.
See FI01105 to find the addressed device. The failing item could be any device with the
same IOP address and I/O (SCSI) bus number but with a different device unit number.
If the reference code that called out this FI does not have a problem analysis procedure,
perform SDIOP-PIP16 to isolate the possible failing device.
Analyze hardware problems 265

Table of Contents

Other manuals for IBM iSeries 270

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM iSeries 270 and is the answer not in the manual?

IBM iSeries 270 Specifications

General IconGeneral
BrandIBM
ModeliSeries 270
CategoryServer
LanguageEnglish

Related product manuals