15. Is the SRC 1xxx 8413?
v No: Continue with the next step.
v Yes: Exchange Processor 1. See symbolic FRU “CCIN” on page 303 for the correct part, and
Locations and addresses for location information.
This ends the procedure.
16.
Is the SRC 1xxx 8414?
v No: Continue with the next step.
v Yes: Exchange Processor 2. See symbolic FRU “CCIN” on page 303 for the correct part, and
Locations and addresses for location information.
This
ends the procedure.
17.
Is the SRC 1xxx 8415?
v No: Continue with the next step.
v Yes: Exchange Processor 3. See symbolic FRU “CCIN” on page 303 for the correct part, and
Locations and addresses for location information.
This ends the procedure.
18.
Is the SRC 1xxx 8416?
v No: Continue with the next step.
v Yes: Exchange Processor 4. See symbolic FRU “CCIN” on page 303 for the correct part, and
Locations and addresses for location information.
This ends the procedure.
19.
Is the SRC 1xxx 8423?
v No: Continue with the next step.
v Yes: Exchange Processor 1. See symbolic FRU “CCIN” on page 303 for the correct part, and
Locations and addresses for location information.
This
ends the procedure.
20. Is the SRC 1xxx 8424?
v No: Continue with the next step.
v Yes: Exchange Processor 2. See symbolic FRU “CCIN” on page 303 for the correct part, and
Locations and addresses for location information.
This
ends the procedure.
21.
Is the SRC 1xxx 8425?
v No: Continue with the next step.
v Yes: Exchange Processor 3. See symbolic FRU “CCIN” on page 303 for the correct part, and
Locations and addresses for location information.
This
ends the procedure.
22.
Is the SRC 1xxx 8426?
v No: Go to “Starting point for all problems” on page 2
This ends the procedure.
v Yes: Exchange Processor 4. See symbolic FRU “CCIN” on page 303 for the correct part, and
Locations and addresses for location information.
This
ends the procedure.
Instructions for Models 800, 810, and 825
1. Is the SRC 1xx 8401?
v No: Continue with the next step.
v Yes: Exchange the control panel. See symbolic FRU “CTLPNL” on page 323 for the correct part.
This ends the procedure.
2. Is the SRC 1xxx 8402?
v No: Continue with the next step.
482 iSeries: iSeries Server 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Hardware Problem Analysis and
Isolation

Table of Contents

Other manuals for IBM iSeries 270

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM iSeries 270 and is the answer not in the manual?

IBM iSeries 270 Specifications

General IconGeneral
BrandIBM
ModeliSeries 270
CategoryServer
LanguageEnglish

Related product manuals