v Yes: Prior to exchanging any parts, verify that the processors are installed. If you are in test mode
and have removed all of the processors, disregard this SRC. Otherwise, correct the processors. If
the processors are installed correctly, then exchange the control panel. See symbolic FRU
“CTLPNL” on page 323 for the correct part.
This ends the procedure.
3. Is the SRC 1xxx 8403?
v No: Continue with the next step.
v Yes: Check that processor 1 is connected and seated properly if pluggable and then exchange the
following:
– For Models 800 and 810 as installed: Processor 1. See symbolic FRU “CCIN” on page 303 for
the correct part and Locations and addresses for location information.
– For Model 825: Processor 1. See see symbolic FRU “CCIN” on page 303 for the correct part
and Locations and addresses for location information.
This
ends the procedure.
4. Is the SRC 1xxx 8404?
v No: Continue with the next step.
v Yes: Exchange Processor 2. See symbolic FRU “CCIN” on page 303 for the correct part, and
Locations and addresses for location information. If there is not a Processor 2, see the next FRU.
This ends the procedure.
5. Is the SRC 1xxx 8405?
v No: Continue with the next step.
v Yes: Exchange Processor 3. See symbolic FRU “CCIN” on page 303 for the correct part, and
Locations and addresses for location information. If there is not a Processor 3, see the next FRU.
This ends the procedure.
6. Is the SRC 1xxx 8406?
v No: Continue with the next step.
v Yes: There is not a Processor 4, see the next FRU.
This ends the procedure.
7. Is the SRC 1xxx 8409?
v No: Continue with the next step.
v Yes: No processors are installed. If you are in test mode and have removed all the processors,
disregard this SRC. Otherwise, correct the processors. If the processors are installed correctly,
exchange all processors. See symbolic FRU “CCIN” on page 303 for the correct part, and
Locations and addresses for location information.
This
ends the procedure.
8. Is the SRC 1xxx 840A?
v No: Continue with the next step.
v Yes: Exchange the System backplane. See symbolic FRU “TWRCARD” on page 470 for the
correct part.
This ends the procedure.
9. Is the SRC 1xxx 840B?
v No: Go to step 14 (See page 484).
v Yes: Are the processor and memory cards removable from the system?
– Yes: Continue with the next step.
– No: Go to step 11 (See page 484).
10. Perform the following:
a. Power off the system.
b. Remove all processor and memory cards from the system.
c. Power on the system.
Analyze hardware problems 483