b. From the Use Dedicated Service Tools (DST) display, select Work with disk units—>Work with
disk unit recovery—>Disk unit problem recovery procedures—>Initialize and format disk
unit.
c. Select the disk unit to initialize and format.
d. Press F10 on the confirmation display.
e. The system initializes and formats the new disk unit. The display shows when the status is
complete (this may take 30 minutes or longer).
28.
In this step, you use the ASP, unit, serial number, type, and resource name information that you
recorded in step 19 (See page 550).
Return to the Work with Disk Units display and perform the following:
a. Select Work with disk configuration—>Work with ASP configuration—>Add units to ASPs.
b. Specify the ASP from which the disk units were removed.
c. Select the unit to add to the ASP.
d. When the Confirm Add Units display appears, press Enter to continue. Wait for the next display.
29.
The Add Disk Units function takes several minutes. When it is complete, a message appears stating
whether it was successful.
Was the Add Disk Units function successful?
v Yes: On the Work with ASP Configuration display, select Display disk configuration capacity.
The unit you that added should be shown in the correct ASP.
This ends the procedure.
v No: Continue with the next step.
30.
Do you have more FRUs to exchange?
v Yes: Go to step 26 (See page 551).
v No: Ask your next level of support for assistance.
This
ends the procedure.
Initialize
disk unit and copy to disk: For use by authorized service providers.
1. Perform an IPL to Dedicated Service Tools (DST). (See Dedicated Service Tools (DST) in the iSeries
Service Functions
information.)
Does the Use Dedicated Service Tools (DST) display appear?
v Yes: Continue with the next step.
v No: Repeat this step and then choose one of the following:
If the same system reference code (SRC) occurs again, the customer data is not recoverable.
Go to step 12 (See page 554).
If a different SRC occurs, use it to correct the problem.
This
ends the procedure.
2. Is this a single disk unit system?
v No: Continue with the next step.
v Yes: Perform “Save data and initialize disk unit” on page 546.
This
ends the procedure.
3. Is the failing disk unit the load-source disk unit (disk unit 1 contains the load-source disk unit)?
v Yes: Continue with the next step.
v No: Go to step 17 (See page 555).
4. Find another disk unit on the system and perform the following to install the new disk unit:
a. Power off the system.
552 Hardware (Remove and Replace; Part Locations and Listings)

Table of Contents

Other manuals for IBM iSeries 820

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM iSeries 820 and is the answer not in the manual?

IBM iSeries 820 Specifications

General IconGeneral
BrandIBM
ModeliSeries 820
CategoryServer
LanguageEnglish

Related product manuals