Step 9
(from Step 8)
1. Switch off power to the drawer.
2. Plug the power cable into another outlet on the power distribution bus.
3. Switch on power to the drawer.
Did the Power light come on and stay on, or are the fans operating?
NO The problem is probably located in this drawer. Go to "MAP 1520 --
Power MAP" in the service guide for this drawer.
YES The first circuit breaker is probably defective. Use the second outlet, or
exchange the power distribution bus, and then go to Step 10.
Chapter 5. Maintenance Analysis Procedures (MAPs) 5-15