Table 3-3 (Page 1 of 13). POST Error Codes
Error Code F Code / Description Action / Possible Failing
FRU
00016000
(continued)
F52 Environmental condition
40210011/40210014, slow/locked fan.
EPOW register could not be cleared.
1. Room operating
temperature
2. System fans
3. System board; swap old
VPD module to new
system board
F53 Environmental condition
40210011/40210014, slow/locked fan.
EPOW register successfully cleared.
1. Fan(s)
2. System board; swap old
VPD module to new
system board
3. Service processor if
present
F55 Unsupported EPOW 1. System board; swap old
VPD module to new
system board
2. Service processor if
present
F56 Environmental condition
40111032/40111092/40111042/401110A2,
3.3V/2.5V high/low. EPOW register
could not be cleared.
1. CPU card
2. Power supply
3. System board; swap old
VPD module to new
system board
4. Service processor if
present
00016010 System VPD access failure 1. System board; swap
old VPD module to new
system board
2. If problem persists,
swap new VPD module
onto new system board;
also see step 3)
3. If customer has
protected licensed
software installed then
advise customer to
contact all protected
software suppliers for a
licence update.
00017001 CMOS error was detected due to battery drainage. Replace your battery
00017002 Error was detected in CMOS, CMOS data is gone!
CMOS not yet initialized if battery just replaced.
Replace battery if you
haven't done so.
00017003 Power interruption occurred during last Boot
Sequence update.
Update the Boot Sequence
again.
00017006 Tamper Evident is detected or new battery was just
being installed.
Security violation possible.
Chapter 3. Error Code to FRU Index 3-3