Table 3-3 (Page 2 of 13). POST Error Codes
Error Code F Code / Description Action / Possible Failing
FRU
00017007 Maximum number of tries was reached!!
Time and Date are logged!
Computer is stopping.
Turn machine off and back
on, re-enter password
00017008 Maximum number of tries was reached!!
Computer is stopping.
Turn machine off and back
on, re-enter password
00017013 No power on password entered.
Unattended mode can not be set.
1. Quit unattended mode
2. Set power-on password
3. Retry operation
00017015 Tamper Evident is detected. Security violation or Bad
CMOS battery.
00018000 Bad flash image discovered during system start-up CPU card
00020000 An error occurred during the memory test. Use System Management
Services to test the
memory.
000210y0 An error occurred during the memory test.
y represents memory module slot number
Memory module slot
number y (y = 1 to 8) is
bad or unsupported.
00031100 The keyboard is in the wrong port. Check keyboard cable and
connector.
00031300 Failed to register keyboard interrupt 1. Keyboard
2. System board; swap
old VPD module onto
new system board.
00070000 Service processor POST failure 1. Service processor
2. System board; swap
old VPD module onto
new system board
00070001 CPU card or power supply failure 1. CPU card
2. Power supply
00070006 Slow or stuck fan 1. Fans
2. Service processor, if
present
3. System board; swap
old VPD module onto
new system board
00070007 System over temperature 1. Check for cool air flow
obstructions to the
system
2. Replace system board
if the problem persists;
also swap old VPD
module onto new
system board
3. CPU card
3-4 Service Guide