Table 3-3 (Page 3 of 13). POST Error Codes
Error Code F Code / Description Action / Possible Failing
FRU
00070008 F4F Environmental condition
40200031/40200041, system
board/memory over temperature.
EPOW register successfully cleared.
1. Check for cool air flow
obstructions to the
system
2. Replace system board
if the problem persists;
also swap old VPD
module onto new
system board
3. Memory
F51 Environmental condition
40200033/40200043, system
board/memory critical temperature.
EPOW register successfully cleared.
1. Check for cool air flow
obstructions to the
system
2. Replace system board
if the problem persists;
also swap old VPD
module onto new
system board
3. Memory
00070009 F4B Environmental condition 40200021,
CPU card over temperature. EPOW
register successfully cleared.
1. Check for cool air flow
obstructions to the
system
2. Replace CPU card if
the problem persists
3. System board; swap old
VPD module onto new
system board
F51 Environmental condition 40200023,
CPU card critical temperature. EPOW
register successfully cleared.
1. Check for cool air flow
obstructions to the
system
2. Replace CPU card if
the problem persists
3. System board; swap old
VPD module onto new
system board
00070010 F48 Environmental condition 40100005. AC
loss eminent.
1. Power supply
2. System board; swap old
VPD module onto new
system board
3. Service processor, if
present
F4A Environmental condition
40111052/401110B2/40111062/401110C2,
+-12V high/low. EPOW register
successfully cleared.
1. Power supply
2. System board; swap old
VPD module onto new
system board
Chapter 3. Error Code to FRU Index 3-5