Table 3-3 (Page 7 of 13). POST Error Codes
Error Code F Code / Description Action / Possible Failing
FRU
0210cyyi SCSI DASD error.
c = SCSI Controller ID assigned by search order
PCI slot 1, 2, integrated controller, PCI slot 3
through last.
Example: #1
1st SCSI controller card in slot 2 = ID 0
Integrated SCSI controller = ID 1
Example: #2
Integrated SCSI controller = ID 0
1st SCSI controller card in slot 3 = ID 1
yy = See Table 3-4 on page 3-16
i = SCSI ID( 0 to 9 or A through F). F normally
indicates the controller.
1. Ensure that the
controller and each
device on the SCSI bus
is assigned a unique
SCSI ID.
2. Ensure SCSI bus
terminator is installed
properly.
3. Ensure SCSI
cable/connector are
securely connected and
not damaged.
4. SCSI Disk Device
connected to SCSI
adapter "c" and
assigned SCSI ID="i".
0211cyyi SCSI tape error.
c = SCSI Controller ID assigned by search order
PCI slot 1, 2, integrated controller, PCI slot 3
through last.
Example: #1
1st SCSI controller card in slot 2 = ID 0
Integrated SCSI controller = ID 1
Example: #2
Integrated SCSI controller = ID 0
1st SCSI controller card in slot 3 = ID 1
yy = See Table 3-4 on page 3-16
i = SCSI ID( 0 to 9 or A through F). F normally
indicates the controller.
1. Ensure that the
controller and each
device on the SCSI bus
is assigned a unique
SCSI ID.
2. Ensure SCSI bus
terminator is installed
properly.
3. Ensure SCSI
cable/connector are
securely connected and
not damaged.
4. SCSI Tape Device
connected to SCSI
adapter "c" and
assigned SCSI ID="i".
Chapter 3. Error Code to FRU Index 3-9