Table 3-3 (Page 8 of 13). POST Error Codes
Error Code F Code / Description Action / Possible Failing
FRU
0215cyyi SCSI CDROM error.
c = SCSI Controller ID assigned by search order
PCI slot 1, 2, integrated controller, PCI slot 3
through last.
Example: #1
1st SCSI controller card in slot 2 = ID 0
Integrated SCSI controller = ID 1
Example: #2
Integrated SCSI controller = ID 0
1st SCSI controller card in slot 3 = ID 1
yy = See Table 3-4 on page 3-16
i = SCSI ID( 0 to 9 or A through F). F normally
indicates the controller.
1. Ensure that the
controller and each
device on the SCSI bus
is assigned a unique
SCSI ID.
2. Ensure SCSI bus
terminator is installed
properly.
3. Ensure SCSI
cable/connector are
securely connected and
not damaged.
4. SCSI CDROM Device
connected to SCSI
adapter "c" and
assigned SCSI ID="i".
0243025y The Graphics Controller, DAC, Frame Buffer,
Graphics Function test failed.
Graphic PCI card in slot y
40100005 A loss of system power detected. Possible main power loss.
If not, replace power
supply.
40111002 An unknown power problem detected. 1. Power supply
2. System board; swap
old VPD module to new
system board
3. Service processor, if
present
40111022 A high 5.0 voltage reading detected. 1. Power supply
2. CPU card
40111032 A high 3.3 voltage reading detected. 1. CPU card
2. Power supply
40111042 A high 2.5 voltage reading detected. 1. CPU card
2. Power supply
40111052 A high +12 voltage reading detected. 1. Power supply
2. System board; swap
old VPD module to new
system board
40111062 A high −12 voltage reading detected. 1. Power supply
2. System board; swap
old VPD module to new
system board
40111082 A low 5.0 voltage reading detected. 1. Power supply
2. CPU card
3-10 Service Guide