Table 3-3 (Page 9 of 13). POST Error Codes
Error Code F Code / Description Action / Possible Failing
FRU
40111092 A low 3.3 voltage reading detected. 1. CPU card
2. Power supply
401110A2 A low 2.5 voltage reading detected. 1. CPU card
2. Power supply
401110B2 A low +12 voltage reading detected. 1. Power supply
2. System board; swap
old VPD module to new
system board
401110C2 A low 12 voltage reading detected. 1. Power supply
2. System board; swap
old VPD module to new
system board
40200001 An unknown cooling problem detected. Cooling problem; check
system fans.
40200021 A CPU temperature warning detected. Over temperature on CPU
card.
40200023 A critical CPU temperature condition detected. Critical temperature on
CPU card.
40200031 An I/O planar temperature warning detected. Over temperature on
system board.
40200033 A critical I/O planar temperature condition detected. Critical temperature on
system board.
40200041 A memory temperature warning detected. Over temperature on
system board.
40200043 A critical memory temperature condition detected. Critical temperature on
system board.
40210011 A slow fan detected. Check:
1. Room operating
temperature
2. System fans
40210014 A stopped fan detected. Failing fan.
Chapter 3. Error Code to FRU Index 3-11