Table 3-3 (Page 10 of 13). POST Error Codes
Error Code F Code / Description Action / Possible Failing
FRU
40A00000 System firmware IPL failure. 1. Surveillance mode
control is from the
Service Processor (SP)
Menus.
2. Verify that the system
firmware supports SP
surveillance.
3. CPU card
4. System board
5. Service processor
6. If the problem still
exists, go to MAP 1540.
7. If the problem persists,
call the support center
for assistance.
40B00000 The operating system surveillance interval
exceeded.
1. Surveillance mode
control is from the
Service Processor(SP)
Menus.
2. Verify that the
Operating System (OS)
Heartbeat Utility is
installed and has been
activated.
3. Check for errors or
unusual conditions that
might prevent the OS
from reporting
Heartbeat messages;
such as system dump,
machine check or
checkstop error.
Review the error log.
4. System board; swap
old VPD module to new
system board
5. Service processor
6. If the problem persists,
call the support center
for assistance.
40D00003 An unknown slow shutdown commanded. Critical cooling problem.
40D00004 An unknown fast shutdown commanded. Locked fan failure detected.
80001200 The firmware recovery information could not be
written to the diskette.
1. Check diskette media
write protect tab.
2. Diskette drive
3-12 Service Guide