Table 3-3 (Page 12 of 13). POST Error Codes
Error Code F Code / Description Action / Possible Failing
FRU
80002400 The firmware module is not supported.
Firmware update cancelled.
Flash module on CPU card
is malfunctioning.
80002500 The firmware module is not supported.
Firmware update cancelled.
Flash module on CPU card
is malfunctioning.
80002600 The firmware module is write protected. 1. Turn the system off and
then back on.
2. Retry operation
3. CPU card
4. If problem persists, call
support center for
assistance.
80002700 Backup recovery diskette is not inside the drive. Insert backup diskette
80002800 Update system firmware diskette is not inside the
drive.
Insert diskette
80072000 The service processor is not installed. Service
processor update cancelled.
1. Install the service
processor
2. Retry operation
91001100 Remote IPL error. Insufficient memory. 1. Run memory test,
replace defective
memory module.
2. This system has
insufficient memory for
this operation.
91001200 Remote IPL error. Incorrect IP format for client IP
address.
Change/Update IP format
91001300 Remote IPL error. Incorrect IP format for server IP
address.
Change/Update IP format
91001400 Remote IPL error. Incorrect IP format for gateway
IP address.
Change/Update IP format
91001500 Remote IPL error. Incorrect IP format for netmask. Change/Update IP format
91001600 Remote IPL error. Error writing to NVRAM. System board; swap old
VPD module onto new
system board
91001700 Remote IPL error. Ethernet adapter not found. Ensure network card is
properly installed.
91001900 Remote IPL error. Token-Ring adapter not found. Ensure network card is
properly installed.
91002000 Remote IPL error. No network adapters
recognized.
Ensure network card is
properly installed.
91002200 Remote IPL error. Ping failed. Possible IP address or
network problem.
M0CON000 The system hung during POST. Go to MAP 1540.
3-14 Service Guide