Table 3-5 (Page 7 of 10). Firmware Checkpoints.
Checkpoint Description Action/
Possible Failing FRU
E1E4 Initialize Super I/O with default
values.
See the note on 3-30.
E1E5 XCOFF boot image initialization. See the note on 3-30.
E1E6 Set up early memory allocation
heap.
See the note on 3-30.
E1E7 PE boot image initialization. See the note on 3-30.
E1E8 Initialize primary diskette drive
(polled mode).
See the note on 3-30.
E1E9 ELF boot image initialization. See the note on 3-30.
E1EA Firmware flash corrupted, load from
diskette.
Ensure that the diskette installed
contains recovery image appropriate
for this system unit.
The System Management Services
recovery procedure for the flash
EEPROM should be executed. See
“Update” on page 6-19.
If the diskette is installed with the
correct recovery image, then
suspect:
1. Diskette
2. Diskette drive
3. Diskette cable
4. I/O board (See notes on 3-1.)
See the note on 3-30.
E1EB Verify flash EPROM recovery
image.
Ensure that the diskette installed
contains recovery image appropriate
for this system unit.
The System Management Services
recovery procedure for the flash
EEPROM should be executed. See
“Update” on page 6-19.
If the diskette is installed with the
correct recovery image, then
suspect:
1. Diskette
2. Diskette drive
3. Diskette cable
4. I/O board (See notes on 3-1.)
See the note on 3-30.
E1EC Get recovery image entry point See the note on 3-30.
E1ED Invalidate instruction cache See the note on 3-30.
Chapter 3. Error Code to FRU Index 3-39