Table 5-1 (Page 7 of 8). Service Request Numbers
SRN FRU List % Problem
D0000 Disk drive module (See “Hot
Swap Disk Drives” on
page 7-10.)
100 Description: The using system cannot
configure the disk drive module. This is
probably a software problem.
Action:
1. Try again to configure the disk drive
module.
2. If the problem remains, go to “Soft-
ware and Microcode Errors” on
page 5-2 before exchanging the FRU.
D0100 Disk drive module (See “Hot
Swap Disk Drives” on
page 7-10.)
100 Description: Unable to clear a disk drive
module reservation.
Action: Exchange the FRU for a new
FRU.
D0101 Disk drive module (See “Hot
Swap Disk Drives” on
page 7-10.)
100 Description: The disk drive module has
been reserved since the diagnostics
started. The disk drive module is in use.
Action: Release the disk drive module,
and run the diagnostics again.
D0200 Disk drive module (See “Hot
Swap Disk Drives” on
page 7-10.)
100 Description: The disk drive module timed
out while the diagnostics were running.
Action: Rerun the diagnostics. If the
problem remains, exchange the FRU for a
new FRU.
D0300 Disk drive module (See “Hot
Swap Disk Drives” on
page 7-10.)
100 Description: The disk drive module failed
the diagnostic test.
Action: Exchange the FRU for a new
FRU.
D0400 Disk drive module (See “Hot
Swap Disk Drives” on
page 7-10.)
100 Description: The disk drive module is not
ready while the diagnostics are running.
Action: Rerun the diagnostics. If the
problem remains, exchange the FRU for a
new FRU.
D0450 None Description: A format operation is in
progress. The format operation that was
started on this disk drive module has not
yet finished. A format operation can take
up to 30 minutes to run.
Action: Wait for the format operation to
finish before you run the diagnostics
again. You can observe the progress of
the format operation by running the format
service aid again on this disk drive
module.
Chapter 5. SSA Software and Microcode Errors 5-9