Table 5-1 (Page 8 of 8). Service Request Numbers
SRN FRU List % Problem
D0460 None Description: A format operation has been
degraded. The format operation that was
started on this disk drive module did not
finish. Possibly, the disk drive module
was switched off while the format opera-
tion was running.
Action: Run the format service aid to
format this disk drive module.
D4000 SSA adapter card (See the
installation and service guide
for the using system.).
100 Description: The diagnostics cannot con-
figure the SSA adapter.
Action: Exchange the FRU for a new
FRU.
D4100 SSA adapter card (See the
installation and service guide
for the using system.)
100 Description: The diagnostics cannot open
the SSA adapter.
Action: Exchange the FRU for a new
FRU.
D4300 SSA adapter card (See the
installation and service guide
for the using system.)
100 Description: The diagnostics have
detected an SSA adapter POST failure.
Action: Exchange the FRU for a new
FRU.
D44xx SSA adapter card (See the
installation and service guide
for the using system.)
100 Description: The diagnostics have
detected that the SSA adapter has cor-
rupted the microcode, but cannot down-
load a new version of the microcode.
Action: Exchange the FRU for a new
FRU.
Note: In this SRN, an x represents a
digit 0 through F.
DFFFF SSA adapter card (See the
installation and service guide
for the using system.)
100 Description: A command or parameter
that has been sent or received is not valid.
This problem is caused either by the SSA
adapter or by an error in the microcode.
Action: Go to “Software and Microcode
Errors” on page 5-2 before exchanging
the FRU.
5-10 RS/6000 Enterprise Server Model H50 Installation and Service Guide