Table 3-1 (Page 11 of 26). Firmware Error Codes.
Error Code Description Action / Possible Failing FRU
2B2xxx22 Processor disabled. CPU Card.
Where xxx indicates the processor type
as follows:
000 166 Mhz 1 or 2 way
Processor card
200 166 Mhz 1 or 2 way
Processor card
211 Down level VPD. Contact
service person.
251 166 Mhz 1 way Processor
card
261 166 Mhz 2 way Processor
card
451 332 Mhz 1 way Processor
card
461 332 Mhz 2 way Processor
card
2B2xxx31 Processor failed. CPU Card.
See error code 2B2xxx22 for xxx defi-
nitions.
2B2xxx42 Unsupported processor type. CPU Card.
See error code 2B2xxx22 for xxx defi-
nitions.
2BA00xxx Service Processor
2BA00000 Service processor POST failure. 1. Unplug the system power cable
and wait until the system power
indicator remains off and the oper-
ator panel is blank.
2. Plug the system power cable back
in and retry the operation.
3. Replace the service processor
card.
4. Replace the I/O board. (See notes
on 3-1.)
2BA00012 Service processor reports self-test
failure.
1. Unplug the system power cable
and wait until the system power
indicator remains off and the oper-
ator panel is blank.
2. Plug the system power cable back
in and retry the operation.
3. Replace the service processor
card.
4. Replace the I/O board. (See notes
on 3-1.)
2BA00013 Service processor reports bad NVRAM
CRC.
1. If problem persists, replace battery.
2. Replace the I/O board. (See notes
on 3-1.)
3-12 RS/6000 Enterprise Server Model H50 Installation and Service Guide