Table 3-1 (Page 15 of 26). Firmware Error Codes.
Error Code Description Action / Possible Failing FRU
2BA00313 Service Processor reports Generic
Power Alert.
1. Replace Power Supply.
2. Replace I/O Board. (See notes on
3-1.)
2BA00314 Service Processor reports 5V Over
Voltage Alert.
1. Replace Power Supply.
2. Replace I/O Board. (See notes on
3-1.)
2BA00315 Service Processor reports 5V Under
Voltage Alert.
1. Replace Power Supply.
2. Replace I/O Board. (See notes on
3-1.)
2BA00316 Service Processor reports 3.3V Over
Voltage Alert.
1. Replace Power Supply.
2. Replace I/O Board. (See notes on
3-1.)
2BA00317 Service Processor reports 3.3V Under
Voltage Alert.
1. Replace Power Supply.
2. Replace I/O Board. (See notes on
3-1.)
2BA00318 Service Processor reports 2.5V Over
Voltage Alert.
1. Replace Power Supply.
2. Replace I/O Board. (See notes on
3-1.)
2BA00319 Service Processor reports 2.5V Under
Voltage Alert.
1. Replace Power Supply.
2. Replace I/O Board. (See notes on
3-1.)
2BA00320 Service Processor reports +12V Over
Voltage Alert.
1. Replace Power Supply.
2. Replace I/O Board. (See notes on
3-1.)
2BA00321 Service Processor reports +12V Under
Voltage Alert.
1. Replace Power Supply.
2. Replace I/O Board. (See notes on
3-1.)
2BA00322 Service Processor reports -12V Over
Voltage Alert.
1. Replace Power Supply.
2. Replace I/O Board. (See notes on
3-1.)
2BA00323 Service Processor reports -12V Under
Voltage Alert.
1. Replace Power Supply.
2. Replace I/O Board. (See notes on
3-1.)
2BA00324 Service Processor reports 5V Standby
Over Voltage Alert.
1. Replace Power Supply.
2. Replace I/O Board. (See notes on
3-1.)
2BA00325 Service Processor reports 5V Standby
Under Voltage Alert.
1. Replace Power Supply.
2. Replace I/O Board. (See notes on
3-1.)
2BA00326 Service Processor reports PCI Expan-
sion Card 5V Over Voltage Alert.
1. Replace Power Supply.
2. Replace I/O Board. (See notes on
3-1.)
3-16 RS/6000 Enterprise Server Model H50 Installation and Service Guide