Table 3-1 (Page 18 of 26). Firmware Error Codes.
Error Code Description Action / Possible Failing FRU
2BA00360 Service Processor reports Slow DASD
Fan #1.
1. Replace DASD Fan 1.
2. If problem persists, replace Power
Supply.
3. Replace I/O Board. (See notes on
3-1.)
2BA00361 Service Processor reports Slow DASD
Fan #2.
1. Replace DASD Fan 2.
2. If problem persists, replace Power
Supply.
3. Replace I/O Board. (See notes on
3-1.)
2BA00362 Service Processor reports Slow DASD
Fan #3.
1. Replace DASD Fan 3.
2. If problem persists, replace Power
Supply.
3. Replace I/O Board. (See notes on
3-1.)
2BA00363 Service Processor reports Slow DASD
Fan #4.
1. Replace DASD Fan 4.
2. If problem persists, replace Power
Supply.
3. Replace I/O Board. (See notes on
3-1.)
2BA00364 Service Processor reports Locked
DASD Fan #1.
1. Remove Obstruction from DASD
Fan 1.
2. Replace DASD Fan 1.
3. If problem persists, replace Power
Supply.
4. Replace I/O Board. (See notes on
3-1.)
2BA00365 Service Processor reports Locked
DASD Fan #2.
1. Remove Obstruction from DASD
Fan 2.
2. Replace DASD Fan 2.
3. If problem persists, replace Power
Supply.
4. Replace I/O Board. (See notes on
3-1.)
2BA00366 Service Processor reports Locked
DASD Fan #3.
1. Remove Obstruction from DASD
Fan 3.
2. Replace DASD Fan 3.
3. If problem persists, replace Power
Supply.
4. Replace I/O Board. (See notes on
3-1.)
Chapter 3. Error Code to FRU Index 3-19