Attention: To avoid breaking the retaining clips or damaging the
ServeRAID-MR10is SAS/SATA adapter connector, open and close the clips
gently.
3. Remove the side cover (see “Removing the side cover” on page 26.
4. Rotate the rear adapter-retention bracket to the open (unlocked) position.
5. Remove the screw that secures the expansion-slot cover to the chassis (if no
adapter is installed in the slot). Store the expansion-slot cover and screw in a
safe place for future use.
Note: Expansion-slot covers must be installed on all vacant slots. This
maintains the electronic emissions standards of the server and ensures proper
ventilation of server components.
6. Open the retaining clips on each end of the ServeRAID-MR10is adapter
connector.
7. Touch the static-protective package that contains the ServeRAID-MR10is
adapter to any unpainted metal surface on the server; then, remove the
ServeRAID-MR10is adapter from the package and place it on a
static-protective surface.
Chapter 2. Installing options 61