ICE i18B/i18C
9
OPERATOR MANUAL
1) Remove the drain hose from the holder, and place the drain hose over the oor drain. Twist off
the drain hose plug to begin the draining process.
2) Clean the recovery tank after every use. Use a fresh water hose to rinse out the recovery
tank. Be careful not to spray water into the oat shut-off mechanism.
If you are storing the machine for any period of time, keep the cover tank open
so the tank can dry completely and smell fresh.
DRAINING THE RECOVERY (DIRTY) TANK
DRAINING THE SOLUTION (CLEAN) TANK
Any time scrubbing operation is completed, the solution tank should be drained
and cleaned.
1) Pull down on the clear tube (back left of the machine) to remove it from the hose barb. This
will allow the solution to ow freely into a bucket or oor drain.
2) Rinse the solution tank with clean water after every use. This will help prevent chemical
buildup and clogging of the solution lines.
3) Once tank is rinsed, ushed and drained, reconnect the clear tube to the hose barb. Be sure
the tube is pushed all the way up on the hose barb.
4) Screw off the cover of the water lter(11) to compeletly exhaust the tank and check the lter
screen, clean it up if necessary.
5) Screw up the cover of the water lter(11),bu sure to install the screen and the "O" ring in the
correct position.
lter screen
"O" ring
lter cover
BATTERY CHARGING (ONLY FOR i18B)
WARNNING: Fire or explosion hazard. Batteries may emit hydrogen gas. Keep
sparks and open flame away. Keep battery compartment open when charging.
NOTE:
Use only approved chargers with the following specications:
- Automatic shut off circuit.
- Deep cycle charging.
- Output current of 8-15 Amps.
- Output voltage of 24 volts.
Each machine was equipped with on-board charger and batteries, please use oringinal parts
only.