Reliable Operations &
Longevity
• Ice is digested and sanitation and bacteria control must
be checked to ensure the machine is safe
by keeping it clean.
• 80-85% of machine failures are due to poor install, lack
of cleaning, inadequate water treatment,
or airborne slime (Bacteria).
• Citryne by Systems IV for all machines with pH over 7.0
• Carbon filtration removes chlorine. If there is slime or
growth inside of the machine it is from airborne
particulate. Carbon removes chlorine.
• Cleaning requires both Ice machine cleaner & sanitizer
and should be done under good conditions
1-2 times per year.
35
Citryne Water Filtration