■ REQUIRED TEST EQUIPMENT
Note: [MPT] versions must use ‘CS-F600’ instead of ‘CS-F500’.
5-1 PREPARATION
When you adjust the contents on pages 5-4 and 5-5, SOFT-
WARE ADJUSTMENT, the optional CS-F500 ADJ ADJUSTMENT
SOFTWARE (Rev. 1.0 or later), *OPC-1122 JIG CABLE (modified
OPC-1122 CLONING CABLE; see illustration below) are required.
■ SYSTEM REQUIREMENTS
• IBM PC compatible computer with an RS -232C serial port
(38400 bps or faster)
• Microsoft Windows 95/98 or Windows ME
• Intel Pentium 100 MHz processor or faster
• At least 16 MB RAM and 10 MB of hard disk space
• 640×480 pixel display (800×600 pixel display recommended)
■ ADJUSTMENT SOFTWARE INSTALLATION
q Boot up Windows.
- Quit all applications when Windows is running.
w Insert the ‘CS-F500’ into the appropriate CD-ROM drive.
e Select ‘Run’ from the [Start] menu.
r Type the setup program name using the full path name,
then push [Enter] key.
(ex. D:\CSF500ADJ\disk1\Setup.exe)
t Follow the prompts.
y Program group ‘CS-F500 ADJ’ appears in the ‘Programs’
folder of the [Start] menu.
■ STARTING SOFTWARE ADJUSTMENT
q Connect IC-F610, F620 or F621 and PC with *OPC-1122
JIG CABLE.
w Turn the transceiver power ON.
e Boot up Windows, and click the program group ‘CS-F500
ADJ’ in the ‘Programs’ folder of the [Start] menu, then
CS-F500 ADJ’s window appears.
r Click ‘Connect’ on the CS-F500’s window, then appears
IC-F610, F620 or F621’s up-to-date condition.
t Set or modify adjustment data as desired.
5 - 1
EQUIPMENT
DC power supply
RF power meter
(terminated type)
Frequency counter
FM deviation meter
DC voltmeter
GRADE AND RANGE
Output voltage : 13.2 (13.6) V DC
Current capacity : 20 A or more
Measuring range : 1–75 W
Frequency range : 300–600 MHz
Impedance : 50 Ω
SWR : Less than 1.2 : 1
Frequency range : 0.1–600 MHz
Frequency accuracy : ±1 ppm or better
Sensitivity : 100 mV or better
Frequency range : DC–600 MHz
Measuring range : 0 to ±10 kHz
Input impedance : 50 kΩ/V DC or better
EQUIPMENT
Audio generator
Standard signal
generator (SSG)
Oscilloscope
AC millivoltmeter
External speaker
Attenuator
GRADE AND RANGE
Frequency range : 300–3000 Hz
Measuring range : 1–500 mV
Frequency range : 0.1–600 MHz
Output level : 0.1 µV–32 mV
(–127 to –17 dBm)
Frequency range : DC–20 MHz
Measuring range : 0.01–20 V
Measuring range : 10 mV–10 V
Input impedance : 4 Ω
Capacity : 7 W or more
Power attenuation : 50 or 60 dB
Capacity : 100 W or more
SECTION 5 ADJUSTMENT PROCEDURES