4. ZERO-TRACKING 2Er0.1 On (default)
2Er0.0 Off
Zero-tracking is a feature which automatically restores the scale to zero, by “tracking out” small
amounts of dung and dirt left on the scale. It should be enabled for most weighing applications.
Use ZERO (+) to change the setting.
To accept the displayed setting and step on to the next one, press DRAFT ().
To accept the displayed setting and step back to the previous one, press STATS ().
To save this setting and exit Set-Up, press WEIGH.
5. DISPLAY RELEASE rELS.0 Off (default)
rELS.1 On
The standard factory setting is Display Release OFF, which in HOLD mode keeps the last weighing
locked on the display, until the next weighing. For Display Release ON, when the weighed animal is
removed from the scale, the weight will not remain locked on the display.
Use ZERO (+) to change the setting.
To accept the displayed setting and exit Set-Up, press DRAFT ().
To accept the displayed setting and step back to the previous one, press STATS ().
On exit from User Set-Up, ’sAuEd’ is displayed while the settings are being stored. The indicator
then returns to the normal weighing mode.
Page 8 FX15+ Manual 06Nov19