STATS KEY
Statistics are stored in a single file in permanent memory. Normally statistics would be cleared at the
start of a new weighing session. Alternatively the operator may wish to add new weighings to a
previous weighing session.
Scroll through the statistics with the STATS key. Flashing digits indicate that statistics are being
displayed. They are displayed in the following order:
no. - number of animals weighed
AUG - average weight
tot - first half of total weight (5 digits)
tot - second half of total weight (5 digits)
If the Draft Limit has been set, then draft numbers will also be shown:
HI - number of animals higher in weight than (or equal to) the draft limit
Lo - number of animals lower in weight than the draft limit
A final press of the STATS returns the scale to the weighing mode.
Rather than scrolling through all statistics, you may press WEIGH at any point for an early exit.
CLEARING STATISTICS
All records in the file are cleared by pressing DELETE while any of the statistics are flashing on the
display. The operator is then prompted with the message ’dEL,?’. Press DELETE again within 2
seconds to confirm. ’dELEt’ is displayed if the file has been cleared.
BATTERY VOLTAGE
To display the voltage of the battery, press and hold down STATS for 2 seconds until the voltage is
shown, for example ’12.4 U' for 12.4 volts. The normal operating range should be from 12.0 to
12.8V. Below 12.0V, the battery will soon need to be recharged.
Charging the battery will be faster if the FX15+ is switched off. However you may check that the
charger is working correctly by switching the indicator on and checking the voltage. While charging,
’CHArG' will be shown instead of the voltage.
BLUETOOTH CONNECTED
When a Bluetooth module is factory fitted, you may check whether the FX15+ Bluetooth is currently
connected to another Bluetooth device. Press and hold down DELETE for 2 seconds until the
following is shown:
Conn.1 if connected
Conn.0 if not connected
Page 6 FX15+ Manual 06Nov19