Auto Operation for Soft Dry(only Heating Model)
The Setting temperature will be same that of the auto operation for cooling.
- Compressor ON temperature; Setting temperature +2°F
- Compressor OFF temperature; Setting temperture -1°F
Auto Operation for Heating(only Heating Model)
- Compressor ON temperature; Setting temperature
- Compressor OFF temperature; Setting temperature
+
6°F
- 16 -
Intake-air temp. below 68°F Over 68°F~below 70°F over 86°F
Setting temp. 68°F Intake air temperature +1°F 86°F
Vertical louver auto operation
: In Auto operation mode, when pressing the vertical airflow direction control
button, vertical louver moves as shown below.
MODE0
MODE1
MODE2
MODE3
End
Start
MODE9
(CLOSED)
MODE4
MODE5
MODE6

Related product manuals