Evaluate existing or choose new furnace location based on minimum clearances and dimensions.
General requirements for furnace installation, including leveling and placement.
Specific requirements for installing furnaces in residential garages.
Steps to rotate the venter assembly for different installation configurations.
Requirements for Category I furnace vent installations per codes.
Dedicated venting of a fan assisted furnace into a masonry chimney.
Requirements for venting into a masonry or concrete chimney.
Requirements for maintaining Category I classification with horizontal venting.
Instructions for venting through non-combustible and combustible walls.
Conforming to ANSI/NFPA 211 and state/local codes for chimney inspection.
Requirements for gas type, input, and supply pressure.
Requirements for gas supply line installation, materials, and connections.
Procedures for leak testing gas supply piping and connections.
Requirements for furnace electrical wiring and grounding per local codes.
Instructions for relocating the J-box on N8MPN/L and *8MPN/L models.
Proper thermostat location, mounting, and wiring for furnace operation.
Requirements for return air duct connections (bottom or side only).
Refer to startup procedures in the Users Information Manual.
Gas supply pressure requirements and setting by suppliers.
Procedure for adjusting manifold gas pressure with burners operating.
Sequence for cooling requests, including fan operation and delays.
Sequence for continuous fan operation without heating or cooling.
Sequence for heating requests, including inducer, pilot, and burner operation.
Explanation of flash codes for gas control valve operation and error states.
Field connection diagram for furnace wiring.
Ladder diagram illustrating the electrical control sequence.