<XON> (11H) Resume Reader Transmission
ACTION Resume transmission of data by the unit.
<XOFF> (13H) Pause Reader Transmission
ACTION Stops transmission of data by the unit.
% (25H) Retransmit
ACTION Retransmits the last message sent by the reader.
Use this command when you detect a communication error in a message received from
the reader. The reader re-transmits the last response it transmitted before this request.
The host may request retransmissions as many times as needed.
9 (39H) Version Report
ACTION Transmit version information.
Send this when you want to know the version of the firmware currently loaded.
Example “ID TECH Reader/Writer Version 2.0 061001”
<ESC> (1BH) Abort
ACTION Abort current command and transmit an Acknowledge response (“^” 5EH) if
issued: After a single character “Load Encode Data” command (A, B, C) has been
responded to by the unit. After a double or triple character “Load Encode Data” command
(a3, E_, …) has been responded to by the unit. After the “Arm to Read” or “Encode data”
commands have been responded to by the unit. (The unit would be waiting for a card
swipe to read or encode.)
Note This command byte is not recognized as a command within data strings. It is
processed as a data character instead.
DEL (7FH) Warm Reset
ACTION Abort all current actions and cause the device to execute all initialization
functions. The unit responds exactly as it would for a “power up” cycle. It does not send
the typical acknowledge response (“^” 5EH). See section