EasyManua.ls Logo

IDEAL 61-772 - User Manual

IDEAL 61-772
11 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
#61-772
#61-774
1000A Clamp Meters
w/TightSight™ Display
Instruction Manual
V/
COM
CAT.IV 600V
1000V
750V
CAT.III 1000V
MAX
True RMS
OFF
400
MAX
MIN
V
1000
A
V
HOLD
CAT.IV 600V
1000A
3002010 40
PEAK
CAT.III 1000V
A
61-774
600V
X
000V
750V
DCAC AM
PS
TightSight™ Display
99 Washington Street
Melrose, MA 02176
Fax 781-665-0780
TestEquipmentDepot.com
Question and Answer IconNeed help?

Do you have a question about the IDEAL 61-772 and is the answer not in the manual?

Summary

Safety Information

Warnings

General safety warnings to avoid electric shock, injury, or death.

Cautions

Precautions to protect yourself, including PPE and safe measurement practices.

Operation Modes

High Voltage Warning

How the meter alerts users to dangerous voltage levels.

Auto;Manual Ranging

Explanation of the meter's autoranging and manual ranging modes.

Measuring AC Current

Measurement Procedures

Technical Specifications

General Specifications

Detailed specifications including display, backlight, power, environment, dimensions, and safety compliance.

Accuracy and Ranges

Ranges and Accuracies

Table detailing measurement ranges, accuracies, and overload protection for various functions.

Overview

The IDEAL 1000A Clamp Meters with TightSight™ Display are versatile instruments designed for electrical measurements, offering enhanced safety features and user-friendly operation. These meters are available in two models: 61-772 (true RMS sensing) and 61-774 (true RMS sensing, measures DC current and capacitance).

Function Description:

The clamp meters are primarily used for measuring AC/DC current, AC/DC voltage, and resistance. They also feature audible continuity, capacitance measurement (61-774 model only), and frequency measurement. A key safety feature is the visual and audible indication when voltage is present, even if the meter is set to the wrong function. The TightSight™ bottom display allows for easy viewing of current measurements in tight locations, while the main display shows numerical values and units of measure for all other functions.

Important Technical Specifications:

  • Displays: 3-3/4 digit LCD with 4000 counts for both main and TightSight™ displays.
  • Backlight: Green illumination with auto-off after 4.5 minutes. The TightSight™ display only lights in Amp function to conserve battery.
  • Analog Bargraph: 41 segment LCD with measurements updated 20 times per second.
  • Polarity: Automatic, positive implied, negative (-) polarity indication.
  • Overrange: "OL" indication displayed.
  • Zero: Automatic.
  • Measure Rate: Samples 2 times per second, nominal.
  • Auto Power Off (APO): Automatically powers down after approximately 30 minutes of non-use. This feature can be overridden.
  • Battery Life: 200 hours continuous with Alkaline (61-772), 150 hours continuous with Alkaline (61-774).
  • Low Battery Indication: The battery symbol is displayed when battery voltage drops below operating level.
  • Power Supply: (1) 9V battery (NEDA 1604, JIS 006P, IEC 6F22). Includes an isolated battery compartment.
  • Accuracy: Stated accuracy at 23°C ±5°C, <75% R.H.
  • Temperature Coefficient: 0.1 x (specified accuracy) per °C (0°C to 18°C, 28°C to 50°C).
  • Altitude: 6561.7 ft. (2000m).
  • Operating Environment: 32°F to 122°F (0°C to 50°C) at < 70% R.H.
  • Storage Environment: -4°F to 140°F (-20°C to 60°C) at < 80% R.H. with battery removed.
  • Jaw Opening: Accepts a 2.0" (51mm) conductor.
  • Dimensions: 10.6"H x 4.1"W x 1.9"D (270mmH x 103mmW x 48.5mmD).
  • Weight: 1.1 lbs. (500g) including battery.
  • Safety Rating: Complies with EN 61010-1, EN 61010-2-032, UL 61010-1, IEC 61010-2-032, IEC 61010-031 specifications. Rated for Cat IV-600V/Cat III-1000V. Double Insulation. Pollution degree 2. Indoor use.

Ranges & Accuracies (True RMS Sensing):

  • AC Current (400.0/1000A):
    • 0-600A, 50-60Hz: 1.7% + 10
    • 0-600A, 60-400Hz: 3.0% + 10
    • 600-1000A, 50-60Hz: 2.5% + 10
    • 600-1000A, 60-400Hz: 3.5% + 10
    • Overload Protection: 1000 AAC
  • DC Current (61-774 only, 400.0/1000A):
    • 0-400A: 1.5% + 5
    • 400-800A: 2.0% + 5
    • 800-1000A: 3.0% + 5
    • Overload Protection: 1000 ADC
  • AC Voltage (400.0m/4.000/40.00/400.0/750V):
    • 50-60Hz (400.0m): 1.2% + 8
    • 50-500Hz (4.000/40.00/400.0V): 1.2% + 8
    • 50-500Hz (750V): 1.5% + 8
    • Overload Protection: 1000VDC or 750VAC rms
  • DC Voltage (400.0m/4.000/40.00/400.0/1000V):
    • 0.5% + 2
    • Overload Protection: 1000VDC or 750 VAC rms
  • Resistance (400.0/4.000k/40.00k/400.0k/4.000M/40.00MΩ):
    • 400.0/4.000k/40.00k/400.0kΩ: 1.0% + 4
    • 4.000MΩ: 5.0% + 4
    • 40.00MΩ (specified to 10MΩ): 12.0% + 5
    • Overload Protection: 600 VDC or AC rms
  • Capacitance (61-774 only, 4.000μ/40.00μ/400.0μ/4.000mF):
    • 4.000μF: 3.0% + 10
    • 40.00μ/400.0μF: 3.0% + 5
    • 4.000mF: 5.0% + 20
    • Overload Protection: 600 VDC or AC rms
  • Continuity:
    • Audible indication < 35Ω
    • Response time: 500ms
    • Overload Protection: 600 VDC or AC rms

Usage Features:

  • Tapered Jaws with Hook Tip: Designed for reaching into tight spaces and easier wire separation.
  • Protective Rubber Boot: Enhances durability and grip.
  • Electronic Overload Protection: Available on all ranges.
  • Auto/Manual Ranging Mode: Defaults to autoranging, automatically selecting the best range. Manual range can be selected by pressing the Range button.
  • High Voltage Warning (HI-V): Red LED lights and meter beeps when 30V AC/DC voltage is present, regardless of function, for enhanced safety.
  • Peak Max/Min Feature: Captures peak voltage (VAC) and peak current (AAC) with 1 ms capture time. Displays P+ and P-. Hold for >2 sec to exit. Calibration option available.
  • Max/Min Feature: Records maximum and minimum values over time. Toggles between Max, Min, and Maxmin (real-time reading while capturing max/min). Hold for >2 sec to exit. Auto Power Off must be defeated for recordings over 30 minutes.
  • Data Hold Feature: Locks the current measurement reading on the display. "HOLD" appears when active.
  • Relative Mode (Δ) (61-774 model only): Zeros out the display before measuring DC current by subtracting a non-zero number. Pressing the button again flashes "Δ" and displays the original offset. Hold for >2 sec to exit.
  • Backlight: Green backlight for main display, stays on for 4.5 minutes. TightSight™ display backlight only active in Amp function. Backlight consumes 4x battery power.

Maintenance Features:

  • Battery Replacement:
    1. Ensure test leads are disconnected from circuit or components.
    2. Remove test leads from input jacks on meter.
    3. Remove the two screws from the battery cap.
    4. Remove the battery cap.
    5. Replace with a new 9V battery.
    6. Assemble the battery cap and re-tighten screws.
  • Cleaning: Clean the case with a damp cloth and mild detergent. Do not use abrasives or solvents.
  • Service and Replacement Parts: The unit has no user-serviceable parts. For replacement parts or service information, contact IDEAL INDUSTRIES, INC. at 1-877-201-9005 or visit www.testersandmeters.com. A replacement boot is available.
  • Warranty: Warranted to the original purchaser against defects in material and workmanship for the lifetime of the product. IDEAL INDUSTRIES, INC. will, at its option, replace or repair defective units, subject to verification of the defect or malfunction. The warranty does not cover defects from abuse, neglect, accident, unauthorized repair, alteration, or unreasonable use. Implied warranties are limited to merchantability and fitness for a particular purpose. The manufacturer is not liable for loss of use, incidental, or consequential damages. State laws vary regarding these limitations.

IDEAL 61-772 Specifications

General IconGeneral
BrandIDEAL
Model61-772
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals