EasyManua.ls Logo

IDEC HR6S - Page 18

IDEC HR6S
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18
HR6S Safety Relay Module
HR6S-S
Wiring Example
PLC
COM
0V
Input1
Common reference potential
0V
Semiconductor pulse output
DC24V
K3
K4
M
S2
WH
BK
BU
BN+
HS7A-
DM
ESC
S1 WH
BK BU
BN+
HS7A-
DM
S3
K3
K4
EXT
F1 F2
AC/DC
DC
Power
supply
DC+
Input
Input
Start
CH+
DC+ CH+
CH+
CH+
DC+ CH+
K2
K1
A1 A2 S11 S12 Y1 Y2
S21 S22 Z1B2
N(
-
)
13
14
K3 K4
23
24
S13
S23
L1(
+
)
Function Mode Selector and Input Device Connection Example
Dial 1 Dial 2 Dial 3
Synchronous monitoring: No
Dynamization: Yes
Signal interlock monitoring: Yes
Synchronous monitoring: 2 s / 4 s (S12 rst / S22 rst)
Dynamization: Yes
Signal interlock monitoring: Yes
Synchronous monitoring: 0.5 s
Dynamization: Yes
Signal interlock monitoring: No
Emergency stop switches
Interlock switch Two-hand control switch (IIIA)
DC+ CH+ CH+
S11 S12 S13
DC+ CH+ CH+
S21 S22 S23
S1
S2
S11
S12
S13
安全柵 安全柵
DC+ CH+ CH+
S21
S22
S23
DC+ CH+ CH+
DC+ CH+ CH+
S11 S12 S13
S1
S2
Dial 4 Dial 5
Synchronous monitoring: 0.5 s
Dynamization: Yes
Signal interlock monitoring: Yes
Synchronous monitoring: 0.5 s
Dynamization: Yes
Signal interlock monitoring: No
Two-hand control switch (IIIC)
Interlock switch
(1 NO, 1 NC)
Coded magnetic switch
(1 NO, 1 NC) (*1)
Proximity switch
(1 NO, 1 NC)
DC+ CH+ CH+
S21 S22 S23
S2
DC+ CH+ CH+
S11 S12 S13
S1
DC+ CH+
S11
S12
CH+
S13
DC+ CH+
S21
S22
CH+
S23
*1: Connection examples for coded magnetic switches such as HS7A (IDEC) are also included on the instruction sheet, but certications are not
available.
Designation Explanation
EXT
Connector for optional
expansion module
S1, S2 Non-contact interlock switch
S3 Start switch
K3, K4 Contactor
PLC Programmable controller
F1, F2 Fuse