22
HR6S Safety Relay Module
HR6S-DN
Dial 5 Dial 6
Synchronous monitoring: No
Dynamization: No
Signal interlock monitoring: Yes
Synchronization: 0.5 s
Dynamization: No
Signal interlock monitoring: Yes
2 PNP × 6
DC+ CH+
S11 S12
+
-
CH+
S13
PNP
+
-
PNP
DC+ CH+
S21 S22
+
-
CH+
S23
PNP
+
-
PNP
DC+ CH+
S31 S32
+
-
CH+
S33
PNP
+
-
PNP
DC+ CH+
S41 S42
+
-
CH+
S43
PNP
+
-
PNP
DC+ CH+
S51 S52
+
-
CH+
S53
PNP
+
-
PNP
DC+ CH+
S61 S62
+
-
CH+
S63
PNP
+
-
PNP
Dial 7 Dial 8
Synchronous monitoring: No
Dynamization: No
Signal interlock monitoring: Yes
Synchronization: 0.5 s
Dynamization: No
Signal interlock monitoring: Yes
2 OSSD × 6
DC+ CH+ CH+
S11 S12
OSSD
0 V
ESPE
24 V
OSSD
S13
DC+ CH+ CH+
S21 S22
OSSD
0 V
ESPE
24 V
OSSD
S23
DC+ CH+ CH+
S31 S32
OSSD
0 V
ESPE
24 V
OSSD
S33
DC+ CH+ CH+
S41 S42
OSSD
0 V
ESPE
24 V
OSSD
S43
DC+ CH+ CH+
S51 S52
OSSD
0 V
ESPE
24 V
OSSD
S53
DC+ CH+ CH+
S61 S62
OSSD
0 V
ESPE
24 V
OSSD
S63