1.3. ELECTROLYSIS CELL SPECIFICATIONS
Recommended salinity: 4-6 g/l (4000 – 6000 ppm)
Electrodes: Titanium with SELF-CLEANING coating
Max. recommended pressure: 1 Kg/cm
2
[D-10+ ... D-25+]
3 Kg/cm
2
[D-40(+)]
Temperature: less than 40ºC
Material: methacrylate-based polymer [D-10+ ... D-25+]
polypropylene [D-40(+)]
D-10+ D-18+ D-25+ D-40(+)
Production
(at 25ºC and 6 g/l salinity)
10 g./h. 18 g./h. 25 g./h. 40 g./h.
Minimum flow
2 m
3
/h 4 m
3
/h 5 m
3
/h 8 m
3
/h
Electrode number:
5
additional flow
detector
8
additional flow
detector
8
additional flow
detector
8
additional flow
detector
Pipe connections: Gluing with PVC adhesive Ø 63 Thread F 1 1/2”
1.4. PH-CONTROLLER SPECIFICATIONS
Control output: 220 V/0.5 A max., ON-OFF, triac.
pH measure range: 0.0 – 9.9
pH control range: 7.0 – 7.8
Precision: +/- 0.1
Fuse: 0.5 A
Calibration: Automatic, two modes.
“FAST” : one-point calibration
“STANDARD”: two-point calibration
1.5. ORP-CONTROLLER TECHNICAL SPECIFICATIONS
ORP range: 0 – 999 mV
ORP control range: 650 - 850 mV
Precision: 1 mV
Calibration: Automatic, single-point
1.6. TECHNICAL SPECIFICATIONS OF THE PH/ORP ELECTRODES
The pH/ORP electrodes have an epoxy body and are filled with electrolyte gel. The
electrolyte gel prevents the contamination of the electrode, allowing its installation in
pressurised systems. The electrodes are supplied with a BNC-ended cable and are immersed
in a special conservation solution.
Response time: 95% in less than 30 sec.
pH range (H-035 electrode): 0 - 12
Temperature range 0 - 80 ºC
Max. pressure: up to 1.7 bar
5