WARNING : if the in-out valves of the electrolysis cell are closed simultaneously, the flow
detector will not work correctly, with the consequent risk of cell breakdown. Although this
situation is extremely unusual, it can be easily avoided once the equipment has been installed,
by locking at opened position the return valve to the swimming pool, so it cannot accidentally
be manipulated.
Other installations would only be acceptable if the detection of low or null flow is also allowed.
RECOMMENDED ACCEPTABLE (NOT RECOMMENDED)
Not acceptable installations
9