2.- INSTALLATION INSTRUCTIONS
Recommended installation diagram[models D-10+ ... D-25+]
Recommended installation diagram [models D-40(+), see next page.
2.1. POWER SUPPLY
Always install the POWER SUPPLY of the IDEGIS system VERTICALLY on a solid and rigid
surface (wall) as shown in the recommended installation diagram. The POWER SUPPLY
should be installed in a well-ventilated dry place. The POWER SUPPLY should not be
installed outdoors, and should be installed a bit distant from the electrolysis cell so that it
cannot accidentally suffer water splashes.
Beware of corrosive atmosphere formation due to pH decreasing solutions (specially, those
ones based on hydrochloric acid "HCl". Do not install the IDEGIS SYSTEM near to any stores
of these chemicals. We strongly recommend the use of chemicals based on sodium
bisulphate or diluted sulphuric acid.
Power supply must be connected to the electrical control box of the pool, so that the pump
and the IDEGIS SYSTEM are turned on (and off) simultaneously.
6