ORP control activated from the
system configuration menu
ORP control?
>YES
No
9
8
5
6
4
7
Alarm
Stop
ORP control
System halted by the ORP
controller
ORP control?
>YES
No
9
8
5
6
4
7
Alarm
Stop
ORP control
In all the previous cases, the ALARM led in the control panel will not blink
ALARM
The integrated pH controller has two ALARM LEDs, which are illuminated whenever a pH
value outside the range 6.5 – 8.5 is detected. When the controller detects an active alarm,
control output to the dosing pump is turned-off.
The integrated ORP controller has two alarm LEDs that are activated automatically when the
readings are outside the prefixed range (650 - 850 mV). For security reasons, the controller
turns-off the control output when the upper limit (850 mV) is exceeded.