uTrust TS KEYPAD User Manual
During wiring, make sure that the +VDC lines does not make contact with any other cables, as it might
affect reader functionality/ cause damage to the reader.
6.0 Installation details
Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), local codes,
and the authorities having jurisdiction.
6.1 Parts List
• TS Keypad reader -1
• Screws (A #6-18X1.5" SS ) - 4Nos – Back Plate mounting screws for Wall
• Snake Eye Screw (SMF #6-32X5/16" SS) – 1 No- Top casing mounting security screw
• Screws (SMF #6-32x3/8" SS) - 3 No’s - 1 casing to back plate mounting screw and 2 Junction
Box mounting screws
• Nylon anchor plug -4 No’s
• 6 pin phoenix plug (Phoenix connector version only) – 2 No’s
• Back Plate
6.2 Recommended Infrastructure
All cabling and wiring shall be UL Listed and/or UL Recognized.
• Cable Wiegand - 22AWG Shielded cable. ( Cable P No : ALPHA WIRE, P/N
1299/10C)
• Cable RS485 - RS485 for 1000m** (4000ft) 24AWG STP
• Class 2 Linear DC PS - 6-16 V, 1A min
** Tested in lab conditions up to 115Kbaud
6.3 Connector Information
6.3.1 Pinout diagram