700-604-02A Xwave Repeater Manual
Information LED
The information LED will flash whenever a signal is repeated.
Battery conditions
On = Battery low
Important NiMH battery charging considerations
NiMH cells will not work in temperatures below 10 degrees Celsius.
High temperatures result in higher self-discharge, I.e. hot vehicle
Never mix batteries from different manufacturers or capacities.
Never mix batteries of different chemistries, i.e. NiCd, NiMH, Lithium, Etc.
Never remove batteries while charger is connected.
Around 300-400 charge cycles is the limit for NiMH cells.
Only use 1.2V NiMH AA cells with a capacity of 2100mAh or higher.
Never connect the charger when non-rechargeable batteries are powering the unit.
If there is a loss of AC power, disconnect charger to prevent surge from damaging the
unit when power is restored (Suggestion: use the unit until its empty again, before re-
connecting charger).
Technical specs
Wireless transmission Frequency: 433MHz
Wireless transmission distance: 100m line of sight
Batteries: 3 x ‘AA’ NiMH 1.2V, 2100mAH
DC charge input 12V, 1.5A
Current Draw:
Standby: 35mA
Alarm: 100mA