CONDENSER MAINTENANCE
It is essential to keep the condenser coils clean and free of dust and debris at all times. It is required to periodically clean
the condenser coils with a soft bristle brush or vacuum-cleaner to properly maintain the refrigeration system. Failure to
clean the condenser at regular intervals may cause failure of the refrigeration system and could void the warranty.
1 Remove the rubber cap from the front Grill.
2 Using a small Phillips head screwdriver, remove the two screws as shown above.
3 The front plastic grill can now be removed by pulling it up.
4 Using plastic bristle brush, carefully clean the coil being aware that coils
can bend or be damaged if too much force is used - shown below.
5 Replace grill and utilize the Phillips screwdriver to tighten the screws into
place, replace the rubber caps.
10
MAINTENANCE
Cleaning
Unplug the cooler before cleaning.
Use a soft cloth or sponge with water or soap (non-corrosive mild detergent). After cleaning, wipe the cooler using a
dry cloth to prevent the cooler from rusting.
Do not spray water on the cooler, and do not use hard or steel brushes to clean the cooler.
Do not use organic solvents, boiling water, washing powders or acids while cleaning.
If the cooler will be in a non-operational state for a long period of time, clean as
instructed above, and keep the door open until interior is dry.