SECTION
4
Table
4-2.
Calibration
and
Performance
Checks (Continued)
,-.
.-.
Step
Calibration
Control
Setting
Test
Equipment
(Mode)
Procedure
1.
DVM
to
OUTPUT
BNC
via
unterminated
coax
with
scope
as
monitor.
2.
Adjust
R119
for
0 ±5mv
dc
on
the
DVM.
Ad~ust
R166
for
reading
of
5.
56
±.
010v
(20.0
±O.
036v
p-p).
4.0
4.1
*
WAVEFORMS
Output
Amplifier
Zero
Adjust
FREQ
Mult @ 1K
Dial
@
2.5
WAVEFORM@DC
LEVEL
@
CW
(Max)
DVM-DC
SCOPE-DC
*
4.2
Gain
Adjust
WAVEFORM@
Triangle
DVM-AC
4.3
*
*
Output
Amplifier
Squarewave
Response
FREQ
Mult
@ 1M
Dial
@
3.0
WAVEFORM @ Sq.
1.
Adjust
the
level
for
10v
p-p
on
the
scope.
2.
Adjust
C58
for
ideal
square
waveform.
Over-
shoot
or
aberration
must
be
less
than
5%
p-p.
3.
Measure
rise
and
fall
between
10%
and
90%
of
amplitude
(tr
and
t
f
<60
ns).
*
4.4
Square
Amplitude
Symmetry
WAVEFORM @ Sq
FREQ
Mult @ 1K
LEVEL
@
mid
range
DVM-DC
1.
DVM
to
OUT BNC
via
unterminated
coax.
2..
Adjust
R63
for
0
±5
mv
dc
*
4.5
Square
Amplitude
LEVEL
@ CW (max)
DVM-AC
Measure
11. 11
±O.
24
vac
Adjust
R96
for
0.0
±5
mv
dc.
1.
Connect
the
distortion
analyzer
to
the
output
BNC
via
50-ohm
termi-
nated
coax
with
scope
as
monitor.
2.
Adjust
R77
and
R89
alternately
for
mini-
mum
distortion
.
4.6
Sine
Zero
WAVEFORM @ Sine
DVM-DC
4.7
Sine
Distortion
FREQ
Mult @ 1K
Dial
@ 1. 0
Distortion
Analyzer
Scope
4-5