BL5x-MT-EN-13 page 15/56
Downloading a version of the control board program that differs
from the one previously installed.
As the difference is of level 2 (modification of the version or the
evolution), all of the parameters are returned to their default
values.
WARNING: it is then necessary to set the parameters to the
actual configuration of the equipment and to save them in
MEM1.
Note: it would be wise to keep the parameters values before
changing the program version: Communication parameter
Extract Param (Technician level access).
Downloading a version of the control board program that differs
from the one previously installed.
As the difference is of level 3 (modification of the type), all of the
parameters are returned to their default values and the counters
are reset to 0.
WARNING: it is then necessary to set the parameters to the
actual configuration of the equipment and to save them in
MEM1.
Note: it would be wise to keep the parameters values before
changing the program version: Communication parameter
Extract Param (Technician level access).
Counters reset to zero following the download of a different
program version of level 3 (see Download Chg Lv3).
Change in the type of barrier: selection of curve 229 standard
(Barrier Type parameter under the QUICK START menu).
Change in the type of barrier: selection of curve 229 highway
(Barrier Type parameter under the QUICK START menu).
Change in the type of barrier: selection of curve for BL16, BL32,
BL33, BL52, BL53 (Barrier Type parameter under the QUICK
START menu).
Change in the type of barrier: Selection of curve BLG77 (Barrier
Type parameter under the QUICK START menu).
Change in the type of barrier: selection of the Special curve
(OPTIONS menu) for operation according to the OP
REGULATION and CL REGULATION menus.
Change in the type of barrier: Selection of curve BL223 (Barrier
Type parameter under the QUICK START menu).
Change in the type of barrier: Selection of curve BL40 AVR
(Barrier Type parameter under the QUICK START menu).
Change in the type of barrier: Selection of curve BL40SR
(Barrier Type parameter under the QUICK START menu).
Change in the type of barrier: Selection of curve BL41AVR
(Barrier Type parameter under the QUICK START menu).
Change in the type of barrier: Selection of curve BL41SR
(Barrier Type parameter under the QUICK START menu).
Change in the type of barrier: Selection of curve BL43AVR
(Barrier Type parameter under the QUICK START menu).
Change in the type of barrier: Selection of curve BL43SR
(Barrier Type parameter under the QUICK START menu).
Change in the type of barrier: Selection of curve BL44AVR
(Barrier Type parameter under the QUICK START menu).
Change in the type of barrier: Selection of curve BL44SR
(Barrier Type parameter under the QUICK START menu).